2.0×CSCR starting torque
0.3×PSC starting torque
44 Astarting current at 230 V

The duty

A 1.5 kW workshop compressor on a 230 V single-phase supply must restart against residual pressure: it needs well over its running torque from standstill.

Comparing EMPD single-phase designs at 1.5 kW 4-pole

DesignStarting torqueStarting currentVerdict
CSCR · capacitor start, capacitor run2.0 × MN (20 Nm)5.1 × 8.7 A = 44 AStarts under load ✓
PSC · permanent split capacitor0.3 × MN (3 Nm)4.1 × 8.5 A = 35 AFans only ✗

Supply and protection

  • The 44 A starting current lasts a fraction of a second. A 16 A circuit breaker with a C curve (magnetic trip at 5–10 × rated current) rides through it; a B curve may trip.
  • The start capacitor (200 µF) is switched out by a centrifugal switch or relay once the motor runs; the 30 µF run capacitor stays in circuit for efficiency and power factor.
  • For 60 Hz markets, EMPD winds the motor and selects capacitors for 60 Hz; a 50 Hz motor must not be run on 60 Hz.

Application study: an engineering example worked by EMPD with catalogue data. Your application is confirmed by our engineers before quotation. Send us your duty.

More applications

Hoists & cranes

A 5-tonne hoist: sizing the motor, the brake and its heat

Brake torque is the easy part of a hoist drive. The question that decides brake life is how much energy the brake must absorb on every stop, at 240 stops an hour.

Material handling · North America

A 460 V conveyor drive: 10 HP that can carry 12.5 HP

A North American conveyor needs 9 HP continuously with peaks to 11.5 HP. Choosing the motor means reading nameplate HP, service factor, starting torque and the overload setting together.

Pumps & utilities

Forty pump motors, IE2 to IE3: where the savings really come from

Replacing IE2 pump motors with IE3 looks like simple arithmetic. On centrifugal pumps, the faster IE3 motor quietly raises the pump load and can cancel the saving. Here is the full calculation.

Fans & blowers

Starting a heavy fan: 3.7 seconds, not 14

A large fan has little load torque at low speed but a great deal of inertia. The starting time decides whether the motor survives the start, and the starting method changes it four-fold.

Pumps & conveyors

Star-delta or direct on line? It depends on the load

Star-delta starting cuts the starting current to a third. It also cuts the starting torque to a third, which a pump can live with and a loaded conveyor cannot.

Textile & process lines

Constant torque at low speed on an inverter

A self-ventilated motor cools less as it slows. Running full torque down to 10 Hz needs a different cooling method, not simply a bigger motor.

Mining & remote sites

High and hot: derating for altitude and ambient

Ratings assume 1,000 m and 40 °C. At a 2,500 m site in 45 °C heat, thinner air and hotter surroundings both cut cooling, and the two effects multiply.

Hoists, lifts & automation

Running a brake motor on an inverter

On an inverter, the drive does the stopping and the brake does the holding. Getting the supply and the timing right keeps both safe and lets the brake last for years.

Valve actuators

Valve actuator motors: torque to unseat, not power to run

An actuator motor runs for seconds or minutes at a time but must break a seated valve free. Starting torque and short-time duty decide the motor, not continuous kW.

Let’s build your motor.

Send us output, speed, supply, mounting, duty and quantity. Our engineers reply with a recommendation and a quotation.