0.86combined derating factor
6.4 kWrating needed for a 5.5 kW load
7.5 kWselected motor

The duty

A 5.5 kW pump at a site 2,500 m above sea level, with ambient air up to 45 °C.

Why ratings change

IEC 60034-1 ratings apply up to 1,000 m and 40 °C. Above that, air density falls and the cooling air is warmer, so the same losses raise the winding temperature more.

Typical derating factors

AmbientFactorAltitudeFactor
40 °C1.001,000 m1.00
45 °C0.962,000 m0.94
50 °C0.922,500 m0.90
55 °C0.873,000 m0.86
Combined factor 0.96 × 0.90 = 0.864 Rating needed 5.5 ÷ 0.864 = 6.4 kW → select 7.5 kW A 5.5 kW motor here delivers only 5.5 × 0.864 = 4.75 kW

Using the thermal reserve

EMPD motors use Class F insulation with a Class B temperature rise. The 25 K reserve between the two can sometimes absorb a mild derating without a frame change; EMPD confirms this per rating by calculation, and by heat run where needed. Factors in the table are typical industry values; the final rating is confirmed for your site.

Application study: an engineering example worked by EMPD with catalogue data. Your application is confirmed by our engineers before quotation. Send us your duty.

More applications

Hoists & cranes

A 5-tonne hoist: sizing the motor, the brake and its heat

Brake torque is the easy part of a hoist drive. The question that decides brake life is how much energy the brake must absorb on every stop, at 240 stops an hour.

Material handling · North America

A 460 V conveyor drive: 10 HP that can carry 12.5 HP

A North American conveyor needs 9 HP continuously with peaks to 11.5 HP. Choosing the motor means reading nameplate HP, service factor, starting torque and the overload setting together.

Pumps & utilities

Forty pump motors, IE2 to IE3: where the savings really come from

Replacing IE2 pump motors with IE3 looks like simple arithmetic. On centrifugal pumps, the faster IE3 motor quietly raises the pump load and can cancel the saving. Here is the full calculation.

Fans & blowers

Starting a heavy fan: 3.7 seconds, not 14

A large fan has little load torque at low speed but a great deal of inertia. The starting time decides whether the motor survives the start, and the starting method changes it four-fold.

Pumps & conveyors

Star-delta or direct on line? It depends on the load

Star-delta starting cuts the starting current to a third. It also cuts the starting torque to a third, which a pump can live with and a loaded conveyor cannot.

Textile & process lines

Constant torque at low speed on an inverter

A self-ventilated motor cools less as it slows. Running full torque down to 10 Hz needs a different cooling method, not simply a bigger motor.

Workshops & buildings

A single-phase compressor that has to start under pressure

Reciprocating compressors often restart against pressure in the cylinder. The capacitor design, not the kW rating, decides whether the motor turns.

Hoists, lifts & automation

Running a brake motor on an inverter

On an inverter, the drive does the stopping and the brake does the holding. Getting the supply and the timing right keeps both safe and lets the brake last for years.

Valve actuators

Valve actuator motors: torque to unseat, not power to run

An actuator motor runs for seconds or minutes at a time but must break a seated valve free. Starting torque and short-time duty decide the motor, not continuous kW.

Let’s build your motor.

Send us output, speed, supply, mounting, duty and quantity. Our engineers reply with a recommendation and a quotation.