3.7 sdirect-on-line start
14 sthe same start in star-delta
188 Astarting current for 3.7 s

The duty

A centrifugal fan absorbs 10 kW at 1,475 rpm. Its impeller and the coupling have a moment of inertia of 4.5 kgm² referred to the motor shaft. Fan torque rises with the square of speed.

The motor

EM3-160M-4-11: 11 kW, MN 71.3 Nm, MA 3.0 × MN, MK 3.7 × MN, rotor inertia 0.086 kgm², starting current 9.0 × 20.9 A.

Accelerating torque

Mean motor torque ≈ 0.45 × (M_A + M_K) × M_N = 0.45 × 6.7 × 71.3 = 215 Nm Fan torque at speed = 10,000 ÷ 154.5 rad/s = 64.7 Nm Mean fan torque ≈ 64.7 ÷ 3 = 21.6 Nm (square law) Accelerating torque = 215 − 21.6 = 193 Nm

Starting time

t = J × ω ÷ T_acc = (0.086 + 4.5) × 154.5 ÷ 193 = 3.7 s

For 3.7 s the motor draws about 188 A and the rotor heats rapidly. EMPD checks this time against the permissible starting time of the frame before quotation.

Why star-delta is the wrong answer here

Star torque = 215 ÷ 3 = 72 Nm → accelerating torque 72 − 21.6 = 50 Nm t = 4.586 × 154.5 ÷ 50 = 14 s

Star-delta cuts the current but quadruples the time, so the rotor absorbs far more heat. For high-inertia fans, start direct on line where the supply allows it, or use a soft starter or inverter with a controlled ramp.

Application study: an engineering example worked by EMPD with catalogue data. Your application is confirmed by our engineers before quotation. Send us your duty.

More applications

Hoists & cranes

A 5-tonne hoist: sizing the motor, the brake and its heat

Brake torque is the easy part of a hoist drive. The question that decides brake life is how much energy the brake must absorb on every stop, at 240 stops an hour.

Material handling · North America

A 460 V conveyor drive: 10 HP that can carry 12.5 HP

A North American conveyor needs 9 HP continuously with peaks to 11.5 HP. Choosing the motor means reading nameplate HP, service factor, starting torque and the overload setting together.

Pumps & utilities

Forty pump motors, IE2 to IE3: where the savings really come from

Replacing IE2 pump motors with IE3 looks like simple arithmetic. On centrifugal pumps, the faster IE3 motor quietly raises the pump load and can cancel the saving. Here is the full calculation.

Pumps & conveyors

Star-delta or direct on line? It depends on the load

Star-delta starting cuts the starting current to a third. It also cuts the starting torque to a third, which a pump can live with and a loaded conveyor cannot.

Textile & process lines

Constant torque at low speed on an inverter

A self-ventilated motor cools less as it slows. Running full torque down to 10 Hz needs a different cooling method, not simply a bigger motor.

Workshops & buildings

A single-phase compressor that has to start under pressure

Reciprocating compressors often restart against pressure in the cylinder. The capacitor design, not the kW rating, decides whether the motor turns.

Mining & remote sites

High and hot: derating for altitude and ambient

Ratings assume 1,000 m and 40 °C. At a 2,500 m site in 45 °C heat, thinner air and hotter surroundings both cut cooling, and the two effects multiply.

Hoists, lifts & automation

Running a brake motor on an inverter

On an inverter, the drive does the stopping and the brake does the holding. Getting the supply and the timing right keeps both safe and lets the brake last for years.

Valve actuators

Valve actuator motors: torque to unseat, not power to run

An actuator motor runs for seconds or minutes at a time but must break a seated valve free. Starting torque and short-time duty decide the motor, not continuous kW.

Let’s build your motor.

Send us output, speed, supply, mounting, duty and quantity. Our engineers reply with a recommendation and a quotation.