10 HPnameplate at 460 V 60 Hz
SF 1.2512.5 HP continuous capability
3.6×starting torque over breakaway

The duty

A belt conveyor runs at about 1,750 rpm on a 460 V, 60 Hz supply. It needs 9 HP continuously, with load peaks of up to 11.5 HP for up to 20 minutes per shift when product surges. Breakaway torque on a loaded start is about 160 % of running torque.

Step 1 · Nameplate and service factor

The EMPD IE3 motor EM3-132M-4-7.5 on 460 V 60 Hz is nameplated 10 HP, 1,740 rpm, FLA 13.3 A, with SF 1.25 proven by heat run at type test.

Continuous need 9.0 HP → 90 % of nameplate Peak need 11.5 HP → 115 % of nameplate, inside SF 1.25 (12.5 HP) SF amps 15.4 A at 12.5 HP

Without a service factor, the peaks would push the selection to 15 HP: a heavier, costlier motor running most of its life at 60 % load, where efficiency and power factor fall.

Step 2 · Starting and pull-out torque

Full-load torque = 10 × 5,252 ÷ 1,740 = 30.2 lb-ft Breakaway need = 1.6 × (9 × 5,252 ÷ 1,740) = 43.5 lb-ft Locked-rotor = 3.2 × 30.2 = 96.6 lb-ft → 2.2 × breakaway Breakdown = 3.4 × 30.2 = 102.6 lb-ft → 3.6 × breakaway at running torque

Step 3 · Protection settings

For motors with a marked service factor of 1.15 or more, the US National Electrical Code allows the running overload to be set at up to 125 % of nameplate FLA: 1.25 × 13.3 = 16.6 A. Setting it at the SF amps of 15.4 A protects the winding while letting the peaks through.

Step 4 · Mechanical fit and compliance

  • IEC frame 132 has a shaft height of 132 mm; the NEMA 215T it replaces has 133 mm. Where the OEM's base is drilled for NEMA, EMPD builds NEMA frames 56C to 256T to MG 1 on request.
  • A continuous-duty motor sold in the US must meet NEMA Premium efficiency and be DOE certified. For a 10 HP 4-pole enclosed motor the NEMA Premium nominal value is 91.7 %. The compliance route is a 60 Hz efficiency test by an accredited laboratory and DOE certification before shipment; EMPD discusses this with each US programme.

Result

A 10 HP motor with SF 1.25 replaces a 15 HP selection, runs nearer its best efficiency for most of the shift, and carries the peaks within its proven thermal capability.

Application study: an engineering example worked by EMPD with catalogue data. Your application is confirmed by our engineers before quotation. Send us your duty.

More applications

Hoists & cranes

A 5-tonne hoist: sizing the motor, the brake and its heat

Brake torque is the easy part of a hoist drive. The question that decides brake life is how much energy the brake must absorb on every stop, at 240 stops an hour.

Pumps & utilities

Forty pump motors, IE2 to IE3: where the savings really come from

Replacing IE2 pump motors with IE3 looks like simple arithmetic. On centrifugal pumps, the faster IE3 motor quietly raises the pump load and can cancel the saving. Here is the full calculation.

Fans & blowers

Starting a heavy fan: 3.7 seconds, not 14

A large fan has little load torque at low speed but a great deal of inertia. The starting time decides whether the motor survives the start, and the starting method changes it four-fold.

Pumps & conveyors

Star-delta or direct on line? It depends on the load

Star-delta starting cuts the starting current to a third. It also cuts the starting torque to a third, which a pump can live with and a loaded conveyor cannot.

Textile & process lines

Constant torque at low speed on an inverter

A self-ventilated motor cools less as it slows. Running full torque down to 10 Hz needs a different cooling method, not simply a bigger motor.

Workshops & buildings

A single-phase compressor that has to start under pressure

Reciprocating compressors often restart against pressure in the cylinder. The capacitor design, not the kW rating, decides whether the motor turns.

Mining & remote sites

High and hot: derating for altitude and ambient

Ratings assume 1,000 m and 40 °C. At a 2,500 m site in 45 °C heat, thinner air and hotter surroundings both cut cooling, and the two effects multiply.

Hoists, lifts & automation

Running a brake motor on an inverter

On an inverter, the drive does the stopping and the brake does the holding. Getting the supply and the timing right keeps both safe and lets the brake last for years.

Valve actuators

Valve actuator motors: torque to unseat, not power to run

An actuator motor runs for seconds or minutes at a time but must break a seated valve free. Starting torque and short-time duty decide the motor, not continuous kW.

Let’s build your motor.

Send us output, speed, supply, mounting, duty and quantity. Our engineers reply with a recommendation and a quotation.