EMPD Energy Efficient Motors
Region
Get a quote
Sales & engineering

[email protected]
+91 99445 93322 · WhatsApp

North America · Europe & UK

[email protected]
+1 (215) 800-9836 · +44 7424 878268

Works

S.F. No. 450/3A, Annai Nagar, Othakalmandapam Road, Chettipalayam, Coimbatore 641 201, Tamil Nadu, India

IE3 · 3-phase

EM3-90S-4-1.1

IE3 premium efficiency motor · 1.1 kW · 4 pole · 1430 rpm

IE34 poleFrame 90SX230/400 V · 50 HzIP55 · IC411Duty S1SF 1.15 at 50 HzBIS IS 12615:2026SF 1.25 at 460 V 60 HzCE
Request a quote
IEC 90SX · 230/400 V
IE3 premium efficiency motor
Representative model from frame 90SX dimensions
Tap a partDrag to rotate · scroll to zoom
1.1kWRated output · 50 Hz
1430rpmRated speed
84.1%Efficiency, full load
7.4NmRated torque
2.5ACurrent at 400 V
0.77Power factor
17.5kgWeight, B3
3× MNStarting torque

Performance · 50 Hz, tested values

Output1.1 kW
Poles · synchronous speed4 · 1500 rpm
Rated speed1430 rpm
Rated torque MN7.4 Nm
Current at 230 V4.2 A
Current at 400 V2.5 A
Current at 690 V–
Current at SF 1.15, 400 V2.7 A
Efficiency 100 / 75 / 50 %84.1 / 84.4 / 84
Power factor 100 / 75 / 50 %0.77 / 0.7 / 0.57
Efficiency classIE3 (IEC 60034-30-1)
Locked-rotor torque MA/MN3
Starting current IA/IN7
Breakdown torque MK/MN3.5
Pull-up torque MS/MN2.7
Rotor inertia J0.0037 kgm²
Sound pressure LPA at 1 m48 dB(A)
InsulationClass F, temperature rise class B
Enclosure · coolingIP55 · IC411 TEFC
Ambient−20 °C to +40 °C
Service factor1.15 at 400 V 50 Hz (S1)
Bearings DE / NDE6205ZZ / 6203ZZ

Torque–speed curve indicative

1×2×3×4× MAMKMN037575011251500speed · rpmtorque ÷ MN

Drawn through the catalogue points MA, MS, MK and MN. Request the tested curve for your application.

Part-load performance

40506070809010084.184.484100 % load75 % load50 % load Efficiency %cos φ × 100

Efficiency determined to IEC 60034-2-1. Values on a 400 V winding (230 V for single-phase), subject to IEC tolerances.

60 Hz · for North America

Supply460 V · 60 Hz
Output (calculated)1.26 kW · 1.7 HP
Nameplate HP1½ HP
Speed1715 rpm
Torque5.2 lb-ft · 7.05 Nm
Full-load amps at nameplate HP≈ 2.3 A
Service factor1.25 · heat-run verified
SF amps≈ 2.7 A

About these values

Calculated from EMPD tested 50 Hz / 400 V data (output × 1.15, speed × 1.2) and confirmed by test on order with a 60 Hz test certificate. SF 1.25 proven by heat run at type test; report supplied at first-article approval. Continuous-duty (S1) motors sold in the US must meet NEMA Premium efficiency and be DOE-certified. Please contact EMPD to discuss.

Frames are IEC metric; NEMA frames 56C to 256T built to MG 1 on request. Please confirm certification requirements (e.g. UL / CSA) at enquiry.

Export programme

Dimensions · IM B3, frame 90SX

L 349CBH 90EA 140

Schematic outline for orientation, not to scale for manufacture. Request the certified drawing (PDF / DXF / STEP) with your enquiry.

AFoot hole spacing, end140 mm
BFoot hole spacing, side100 mm
CShaft shoulder to foot hole56 mm
HShaft centre height90 mm
KFoot hole diameter10 mm
LOverall length349 mm
ACBody diameter178 mm
HDOverall height225 mm
DShaft diameter24 mm
EShaft length50 mm
MFlange B5 · pitch circle165 mm
NFlange B5 · spigot130 mm
PFlange B5 · outside diameter200 mm
SFlange B5 · hole diameter12 mm

Mountings B3, B5, B14, B35 and B34 on every rating. Shaft tolerance to IEC 60072. NEMA frames 56C to 256T built to MG 1 on request.

Let’s build your motor.

Send us output, speed, supply, mounting, duty and quantity. Our engineers reply with a recommendation and a quotation.