EBM-A90S-4-1.1

Brake motor · AC brake · 1.1 kW · 4 pole · 1425 rpm

IE24 poleFrame 90S230/400 V · 50 HzIP55 · IC411Duty S4CE
Request a quote
IEC 90S · 230/400 V
Brake motor · AC brake
Representative model from frame 90S dimensions
Tap a partDrag to rotate · scroll to zoom
1.1kWRated output · 50 Hz
1425rpmRated speed
81.4%Efficiency, full load
7.4NmRated torque
2.5ACurrent at 400 V
0.77Power factor
13kgWeight, B3
2.3× MNStarting torque

Performance · 50 Hz, tested values

Output1.1 kW
Poles · synchronous speed4 · 1500 rpm
Rated speed1425 rpm
Rated torque MN7.4 Nm
Current at 230 V–
Current at 400 V2.5 A
Current at 690 V–
Efficiency 100 / 75 / 50 %81.4 / 81.5 / 82
Power factor 100 / 75 / 50 %0.77 / 0.78 / 0.58
Efficiency classIE2 (IEC 60034-30-1)
Locked-rotor torque MA/MN2.3
Starting current IA/IN5.2
Breakdown torque MK/MN2.9
Rotor inertia J0.0034 kgm²
Sound pressure LPA at 1 m48 dB(A)
InsulationClass F, temperature rise class B
Enclosure · coolingIP55 · IC411 TEFC
Ambient−20 °C to +40 °C
Service factorNot applicable to S4 hoist duty; S1 versions SF 1.15 at 50 Hz

Torque–speed curve indicative

1×2×3×4× MAMKMN037575011251500speed · rpmtorque ÷ MN

Drawn through the catalogue points MA, MS, MK and MN. Request the tested curve for your application.

Part-load performance

40506070809010081.481.582100 % load75 % load50 % load Efficiency %cos φ × 100

Efficiency determined to IEC 60034-2-1. Values on a 400 V winding (230 V for single-phase), subject to IEC tolerances.

60 Hz · for North America

Supply460 V · 60 Hz
Output (calculated)1.26 kW · 1.7 HP
Nameplate HP1½ HP
Speed1710 rpm
Torque5.21 lb-ft · 7.06 Nm
Full-load amps at nameplate HP≈ 2.33 A
Service factorNot applicable to S4 hoist duty

About these values

Calculated from EMPD tested 50 Hz / 400 V data (output × 1.15, speed × 1.2) and confirmed by test on order with a 60 Hz test certificate. Continuous-duty (S1) motors sold in the US must meet NEMA Premium efficiency and be DOE-certified. Please contact EMPD to discuss.

Frames are IEC metric; NEMA frames 56C to 256T built to MG 1 on request. Please confirm certification requirements (e.g. UL / CSA) at enquiry.

Export programme

Brake selection · AC brake

100 % of motor torqueEBA-10 · 7.5 Nm
150 % of motor torqueEBA-11 · 12.5 Nm
200 % of motor torque · hoistEBA-11 · 15 Nm
250 % of motor torqueNot offered

Selecting the brake

Spring-applied, fail-safe AC brake. Choose 150 % for general machinery and 200 % for hoists. A red percentage shows the maximum brake torque available for this frame where it is below the column value. Brake coils for 230 V, 400 V or 460 / 575 V AC; manual release, micro switch and force-voltage rectifier options.

Brake sizing tool

Dimensions · IM B3, frame 90S

L 425CBH 90EA 140

Schematic outline for orientation, not to scale for manufacture. Request the certified drawing (PDF / DXF / STEP) with your enquiry.

AFoot hole spacing, end140 mm
BFoot hole spacing, side100 mm
CShaft shoulder to foot hole56 mm
HShaft centre height90 mm
KFoot hole diameter10 mm
LOverall length incl. brake425 mm
ADCentre to terminal box top140 mm
DShaft diameter24 mm
EShaft length50 mm
MFlange B5 · pitch circle165 mm
NFlange B5 · spigot130 mm
PFlange B5 · outside diameter200 mm
SFlange B5 · hole diameter12 mm

Mountings B3, B5, B14, B35 and B34 on every rating. Shaft tolerance to IEC 60072. NEMA frames 56C to 256T built to MG 1 on request.

Let’s build your motor.

Send us output, speed, supply, mounting, duty and quantity. Our engineers reply with a recommendation and a quotation.