EMPD Energy Efficient Motors
Region
Get a quote
Sales & engineering

[email protected]
+91 99445 93322 · WhatsApp

North America · Europe & UK

[email protected]
+1 (215) 800-9836 · +44 7424 878268

Works

S.F. No. 450/3A, Annai Nagar, Othakalmandapam Road, Chettipalayam, Coimbatore 641 201, Tamil Nadu, India

IE3 · 3-phase

EM3-160L-4-15

IE3 premium efficiency motor · 15 kW · 4 pole · 1475 rpm

IE34 poleFrame 160L400/690 V · 50 HzIP55 · IC411Duty S1SF 1.15 at 50 HzBIS IS 12615:2026SF 1.25 at 460 V 60 HzCE
Request a quote
IEC 160L · 400/690 V
IE3 premium efficiency motor
Representative model from frame 160L dimensions
Tap a partDrag to rotate · scroll to zoom
15kWRated output · 50 Hz
1475rpmRated speed
92.8%Efficiency, full load
97.2NmRated torque
28.1ACurrent at 400 V
0.83Power factor
92kgWeight, B3
3.2× MNStarting torque

Performance · 50 Hz, tested values

Output15 kW
Poles · synchronous speed4 · 1500 rpm
Rated speed1475 rpm
Rated torque MN97.2 Nm
Current at 230 V–
Current at 400 V28.1 A
Current at 690 V16.3 A
Current at SF 1.15, 400 V31.1 A
Efficiency 100 / 75 / 50 %92.8 / 93 / 92.3
Power factor 100 / 75 / 50 %0.83 / 0.76 / 0.62
Efficiency classIE3 (IEC 60034-30-1)
Locked-rotor torque MA/MN3.2
Starting current IA/IN9.1
Breakdown torque MK/MN3.5
Pull-up torque MS/MN2.4
Rotor inertia J0.1 kgm²
Sound pressure LPA at 1 m63 dB(A)
InsulationClass F, temperature rise class B
Enclosure · coolingIP55 · IC411 TEFC
Ambient−20 °C to +40 °C
Service factor1.15 at 400 V 50 Hz (S1)
Bearings DE / NDE6309ZZ / 6307ZZ

Torque–speed curve indicative

1×2×3×4× MAMKMN037575011251500speed · rpmtorque ÷ MN

Drawn through the catalogue points MA, MS, MK and MN. Request the tested curve for your application.

Part-load performance

506070809010092.89392.3100 % load75 % load50 % load Efficiency %cos φ × 100

Efficiency determined to IEC 60034-2-1. Values on a 400 V winding (230 V for single-phase), subject to IEC tolerances.

60 Hz · for North America

Supply460 V · 60 Hz
Output (calculated)17.25 kW · 23.13 HP
Nameplate HP20 HP
Speed1770 rpm
Torque68.64 lb-ft · 93.06 Nm
Full-load amps at nameplate HP≈ 25.5 A
Service factor1.25 · heat-run verified
SF amps≈ 29.7 A

About these values

Calculated from EMPD tested 50 Hz / 400 V data (output × 1.15, speed × 1.2) and confirmed by test on order with a 60 Hz test certificate. SF 1.25 proven by heat run at type test; report supplied at first-article approval. Continuous-duty (S1) motors sold in the US must meet NEMA Premium efficiency and be DOE-certified. Please contact EMPD to discuss.

Frames are IEC metric; NEMA frames 56C to 256T built to MG 1 on request. Please confirm certification requirements (e.g. UL / CSA) at enquiry.

Export programme

Dimensions · IM B3, frame 160L

L 605CBH 160EA 254

Schematic outline for orientation, not to scale for manufacture. Request the certified drawing (PDF / DXF / STEP) with your enquiry.

AFoot hole spacing, end254 mm
BFoot hole spacing, side254 mm
CShaft shoulder to foot hole108 mm
HShaft centre height160 mm
KFoot hole diameter15 mm
LOverall length605 mm
ACBody diameter314 mm
HDOverall height400 mm
DShaft diameter42 mm
EShaft length110 mm
MFlange B5 · pitch circle300 mm
NFlange B5 · spigot250 mm
PFlange B5 · outside diameter350 mm
SFlange B5 · hole diameter18.5 mm

Mountings B3, B5, B14, B35 and B34 on every rating. Shaft tolerance to IEC 60072. NEMA frames 56C to 256T built to MG 1 on request.

Let’s build your motor.

Send us output, speed, supply, mounting, duty and quantity. Our engineers reply with a recommendation and a quotation.