EMPD Energy Efficient Motors
Region
Get a quote
Sales & engineering

[email protected]
+91 99445 93322 · WhatsApp

North America · Europe & UK

[email protected]
+1 (215) 800-9836 · +44 7424 878268

Works

S.F. No. 450/3A, Annai Nagar, Othakalmandapam Road, Chettipalayam, Coimbatore 641 201, Tamil Nadu, India

Single-phase

EM1R-100L-4-2.2

Single-phase motor · Capacitor start, capacitor run · 2.2 kW · 4 pole · 1440 rpm

4 poleFrame 100L230 V · 50 HzIP55 · IC411Duty S1SF 1.25 at 460 V 60 HzCE
Request a quote
IEC 100L · 230 V
Single-phase motor · Capacitor start, capacitor run
Representative model from frame 100L dimensions
Tap a partDrag to rotate · scroll to zoom
2.2kWRated output · 50 Hz
1440rpmRated speed
75%Efficiency, full load
14NmRated torque
15ACurrent at 230 V
0.85Power factor
19kgWeight, B3
2× MNStarting torque

Performance · 50 Hz, tested values

Output2.2 kW
Poles · synchronous speed4 · 1500 rpm
Rated speed1440 rpm
Rated torque MN14 Nm
Current at 230 V15 A
DesignCapacitor start, capacitor run
Start capacitor200 µF
Run capacitor25 µF
Efficiency 100 / 75 / 50 %75 / 73 / 69
Power factor 100 / 75 / 50 %0.85 / 0.79 / 0.66
Efficiency classNot classified (single-phase)
Locked-rotor torque MA/MN2
Starting current IA/IN5.3
InsulationClass F, temperature rise class B
Enclosure · coolingIP55 · IC411 TEFC
Ambient−20 °C to +40 °C
Service factor1.0 standard · 1.15 on request

Part-load performance

5060708090100757369100 % load75 % load50 % load Efficiency %cos φ × 100

Efficiency determined to IEC 60034-2-1. Values on a 400 V winding (230 V for single-phase), subject to IEC tolerances.

60 Hz · for North America

Supply115 / 230 V · 60 Hz (wound and fitted with capacitors for 60 Hz)
Output2.2 kW · 2.95 HP
Nameplate HP3 HP
Speed1730 rpm
Torque8.96 lb-ft
FLA at 230 V / 115 V≈ 15.7 A / ≈ 31.4 A
Service factor1.0 standard · 1.15 on request

About these values

Calculated from tested 50 Hz data and confirmed by test on order. A 50 Hz motor must not be run on 60 Hz. In the US, capacitor-start motors for general-purpose use may fall under the DOE small electric motor efficiency standards.

Frames are IEC metric; NEMA frames 56C to 256T built to MG 1 on request. Please confirm certification requirements (e.g. UL / CSA) at enquiry.

Export programme

Dimensions · IM B3, frame 100L

L 368CBH 100EA 160

Schematic outline for orientation, not to scale for manufacture. Request the certified drawing (PDF / DXF / STEP) with your enquiry.

AFoot hole spacing, end160 mm
BFoot hole spacing, side140 mm
CShaft shoulder to foot hole63 mm
HShaft centre height100 mm
KFoot hole diameter12 mm
LOverall length368 mm
ACBody diameter208 mm
HCOverall height250 mm
DShaft diameter28 mm
EShaft length60 mm
MFlange B5 · pitch circle215 mm
NFlange B5 · spigot180 mm
PFlange B5 · outside diameter250 mm
SFlange B5 · hole diameter15 mm

Mountings B3, B5, B14, B35 and B34 on every rating. Shaft tolerance to IEC 60072. NEMA frames 56C to 256T built to MG 1 on request.

Let’s build your motor.

Send us output, speed, supply, mounting, duty and quantity. Our engineers reply with a recommendation and a quotation.