EMPD Energy Efficient Motors
Region
Get a quote
Sales & engineering

[email protected]
+91 99445 93322 · WhatsApp

North America · Europe & UK

[email protected]
+1 (215) 800-9836 · +44 7424 878268

Works

S.F. No. 450/3A, Annai Nagar, Othakalmandapam Road, Chettipalayam, Coimbatore 641 201, Tamil Nadu, India

IE3 · 3-phase

EM3-100L-4-2.2

IE3 premium efficiency motor · 2.2 kW · 4 pole · 1450 rpm

IE34 poleFrame 100LF230/400 V · 50 HzIP55 · IC411Duty S1SF 1.15 at 50 HzBIS IS 12615:2026SF 1.25 at 460 V 60 HzCE
Request a quote
IEC 100LF · 230/400 V
IE3 premium efficiency motor
Representative model from frame 100LF dimensions
Tap a partDrag to rotate · scroll to zoom
2.2kWRated output · 50 Hz
1450rpmRated speed
86.7%Efficiency, full load
14.5NmRated torque
4.6ACurrent at 400 V
0.79Power factor
29.5kgWeight, B3
3.3× MNStarting torque

Performance · 50 Hz, tested values

Output2.2 kW
Poles · synchronous speed4 · 1500 rpm
Rated speed1450 rpm
Rated torque MN14.5 Nm
Current at 230 V8.1 A
Current at 400 V4.6 A
Current at 690 V–
Current at SF 1.15, 400 V5 A
Efficiency 100 / 75 / 50 %86.7 / 87 / 86
Power factor 100 / 75 / 50 %0.79 / 0.7 / 0.57
Efficiency classIE3 (IEC 60034-30-1)
Locked-rotor torque MA/MN3.3
Starting current IA/IN7.3
Breakdown torque MK/MN3.3
Pull-up torque MS/MN3
Rotor inertia J0.0106 kgm²
Sound pressure LPA at 1 m54 dB(A)
InsulationClass F, temperature rise class B
Enclosure · coolingIP55 · IC411 TEFC
Ambient−20 °C to +40 °C
Service factor1.15 at 400 V 50 Hz (S1)
Bearings DE / NDE6206ZZ / 6205ZZ

Torque–speed curve indicative

1×2×3×4× MAMKMN037575011251500speed · rpmtorque ÷ MN

Drawn through the catalogue points MA, MS, MK and MN. Request the tested curve for your application.

Part-load performance

40506070809010086.78786100 % load75 % load50 % load Efficiency %cos φ × 100

Efficiency determined to IEC 60034-2-1. Values on a 400 V winding (230 V for single-phase), subject to IEC tolerances.

60 Hz · for North America

Supply460 V · 60 Hz
Output (calculated)2.53 kW · 3.39 HP
Nameplate HP3 HP
Speed1740 rpm
Torque10.24 lb-ft · 13.88 Nm
Full-load amps at nameplate HP≈ 4.3 A
Service factor1.25 · heat-run verified
SF amps≈ 4.9 A

About these values

Calculated from EMPD tested 50 Hz / 400 V data (output × 1.15, speed × 1.2) and confirmed by test on order with a 60 Hz test certificate. SF 1.25 proven by heat run at type test; report supplied at first-article approval. Continuous-duty (S1) motors sold in the US must meet NEMA Premium efficiency and be DOE-certified. Please contact EMPD to discuss.

Frames are IEC metric; NEMA frames 56C to 256T built to MG 1 on request. Please confirm certification requirements (e.g. UL / CSA) at enquiry.

Export programme

Dimensions · IM B3, frame 100LF

L 442CBH 100EA 160

Schematic outline for orientation, not to scale for manufacture. Request the certified drawing (PDF / DXF / STEP) with your enquiry.

AFoot hole spacing, end160 mm
BFoot hole spacing, side140 mm
CShaft shoulder to foot hole63 mm
HShaft centre height100 mm
KFoot hole diameter12 mm
LOverall length442 mm
ACBody diameter199 mm
HDOverall height267 mm
DShaft diameter28 mm
EShaft length60 mm
MFlange B5 · pitch circle215 mm
NFlange B5 · spigot180 mm
PFlange B5 · outside diameter250 mm
SFlange B5 · hole diameter14.5 mm

Mountings B3, B5, B14, B35 and B34 on every rating. Shaft tolerance to IEC 60072. NEMA frames 56C to 256T built to MG 1 on request.

Let’s build your motor.