EMPD Energy Efficient Motors
Region
Get a quote
Sales & engineering

[email protected]
+91 99445 93322 · WhatsApp

North America · Europe & UK

[email protected]
+1 (215) 800-9836 · +44 7424 878268

Works

S.F. No. 450/3A, Annai Nagar, Othakalmandapam Road, Chettipalayam, Coimbatore 641 201, Tamil Nadu, India

IE3 · 3-phase

EM3-132S-6-3

IE3 premium efficiency motor · 3 kW · 6 pole · 965 rpm

IE36 poleFrame 132SX230/400 V · 50 HzIP55 · IC411Duty S1SF 1.15 at 50 HzBIS IS 12615:2026SF 1.25 at 460 V 60 HzCE
Request a quote
IEC 132SX · 230/400 V
IE3 premium efficiency motor
Representative model from frame 132SX dimensions
Tap a partDrag to rotate · scroll to zoom
3kWRated output · 50 Hz
965rpmRated speed
87%Efficiency, full load
29.5NmRated torque
7.2ACurrent at 400 V
0.69Power factor
57kgWeight, B3
2.3× MNStarting torque

Performance · 50 Hz, tested values

Output3 kW
Poles · synchronous speed6 · 1000 rpm
Rated speed965 rpm
Rated torque MN29.5 Nm
Current at 230 V12.5 A
Current at 400 V7.2 A
Current at 690 V–
Current at SF 1.15, 400 V7.7 A
Efficiency 100 / 75 / 50 %87 / 86.7 / 83
Power factor 100 / 75 / 50 %0.69 / 0.62 / 0.43
Efficiency classIE3 (IEC 60034-30-1)
Locked-rotor torque MA/MN2.3
Starting current IA/IN6.1
Breakdown torque MK/MN2.5
Pull-up torque MS/MN2.2
Rotor inertia J0.032 kgm²
Sound pressure LPA at 1 m58 dB(A)
InsulationClass F, temperature rise class B
Enclosure · coolingIP55 · IC411 TEFC
Ambient−20 °C to +40 °C
Service factor1.15 at 400 V 50 Hz (S1)
Bearings DE / NDE6208ZZ / 6305ZZ

Torque–speed curve indicative

1×2×3× MAMKMN02505007501000speed · rpmtorque ÷ MN

Drawn through the catalogue points MA, MS, MK and MN. Request the tested curve for your application.

Part-load performance

304050607080901008786.783100 % load75 % load50 % load Efficiency %cos φ × 100

Efficiency determined to IEC 60034-2-1. Values on a 400 V winding (230 V for single-phase), subject to IEC tolerances.

60 Hz · for North America

Supply460 V · 60 Hz
Output (calculated)3.45 kW · 4.63 HP
Nameplate HP3 HP
Speed1160 rpm
Torque20.95 lb-ft · 28.4 Nm
Full-load amps at nameplate HP≈ 6.1 A
Service factor1.25 · heat-run verified
SF amps≈ 6.6 A

About these values

Calculated from EMPD tested 50 Hz / 400 V data (output × 1.15, speed × 1.2) and confirmed by test on order with a 60 Hz test certificate. SF 1.25 proven by heat run at type test; report supplied at first-article approval. Continuous-duty (S1) motors sold in the US must meet NEMA Premium efficiency and be DOE-certified. Please contact EMPD to discuss.

Frames are IEC metric; NEMA frames 56C to 256T built to MG 1 on request. Please confirm certification requirements (e.g. UL / CSA) at enquiry.

Export programme

Dimensions · IM B3, frame 132SX

L 489CBH 132EA 216

Schematic outline for orientation, not to scale for manufacture. Request the certified drawing (PDF / DXF / STEP) with your enquiry.

AFoot hole spacing, end216 mm
BFoot hole spacing, side140 mm
CShaft shoulder to foot hole89 mm
HShaft centre height132 mm
KFoot hole diameter12 mm
LOverall length489 mm
ACBody diameter255 mm
HDOverall height323 mm
DShaft diameter38 mm
EShaft length80 mm
MFlange B5 · pitch circle265 mm
NFlange B5 · spigot230 mm
PFlange B5 · outside diameter300 mm
SFlange B5 · hole diameter14.5 mm

Mountings B3, B5, B14, B35 and B34 on every rating. Shaft tolerance to IEC 60072. NEMA frames 56C to 256T built to MG 1 on request.

Let’s build your motor.

Send us output, speed, supply, mounting, duty and quantity. Our engineers reply with a recommendation and a quotation.