EMPD Energy Efficient Motors
Region
Get a quote
Sales & engineering

[email protected]
+91 99445 93322 · WhatsApp

North America · Europe & UK

[email protected]
+1 (215) 800-9836 · +44 7424 878268

Works

S.F. No. 450/3A, Annai Nagar, Othakalmandapam Road, Chettipalayam, Coimbatore 641 201, Tamil Nadu, India

IE3 · 3-phase

EM3-112M-2-4

IE3 premium efficiency motor · 4 kW · 2 pole · 2895 rpm

IE32 poleFrame 112M400/690 V · 50 HzIP55 · IC411Duty S1SF 1.15 at 50 HzBIS IS 12615:2026SF 1.25 at 460 V 60 HzCE
Request a quote
IEC 112M · 400/690 V
IE3 premium efficiency motor
Representative model from frame 112M dimensions
Tap a partDrag to rotate · scroll to zoom
4kWRated output · 50 Hz
2895rpmRated speed
88.5%Efficiency, full load
13.2NmRated torque
7.3ACurrent at 400 V
0.9Power factor
29.5kgWeight, B3
3.9× MNStarting torque

Performance · 50 Hz, tested values

Output4 kW
Poles · synchronous speed2 · 3000 rpm
Rated speed2895 rpm
Rated torque MN13.2 Nm
Current at 230 V–
Current at 400 V7.3 A
Current at 690 V4.2 A
Current at SF 1.15, 400 V8.2 A
Efficiency 100 / 75 / 50 %88.5 / 89.2 / 88.5
Power factor 100 / 75 / 50 %0.9 / 0.85 / 0.74
Efficiency classIE3 (IEC 60034-30-1)
Locked-rotor torque MA/MN3.9
Starting current IA/IN10
Breakdown torque MK/MN4.8
Pull-up torque MS/MN3.8
Rotor inertia J0.0064 kgm²
Sound pressure LPA at 1 m60 dB(A)
InsulationClass F, temperature rise class B
Enclosure · coolingIP55 · IC411 TEFC
Ambient−20 °C to +40 °C
Service factor1.15 at 400 V 50 Hz (S1)
Bearings DE / NDE6206ZZ / 6205ZZ

Torque–speed curve indicative

1×2×3×4×5×6× MAMKMN0750150022503000speed · rpmtorque ÷ MN

Drawn through the catalogue points MA, MS, MK and MN. Request the tested curve for your application.

Part-load performance

6070809010088.589.288.5100 % load75 % load50 % load Efficiency %cos φ × 100

Efficiency determined to IEC 60034-2-1. Values on a 400 V winding (230 V for single-phase), subject to IEC tolerances.

60 Hz · for North America

Supply460 V · 60 Hz
Output (calculated)4.6 kW · 6.17 HP
Nameplate HP5 HP
Speed3475 rpm
Torque9.32 lb-ft · 12.64 Nm
Full-load amps at nameplate HP≈ 6.2 A
Service factor1.25 · heat-run verified
SF amps≈ 7.4 A

About these values

Calculated from EMPD tested 50 Hz / 400 V data (output × 1.15, speed × 1.2) and confirmed by test on order with a 60 Hz test certificate. SF 1.25 proven by heat run at type test; report supplied at first-article approval. Continuous-duty (S1) motors sold in the US must meet NEMA Premium efficiency and be DOE-certified. Please contact EMPD to discuss.

Frames are IEC metric; NEMA frames 56C to 256T built to MG 1 on request. Please confirm certification requirements (e.g. UL / CSA) at enquiry.

Export programme

Dimensions · IM B3, frame 112M

L 382CBH 112EA 190

Schematic outline for orientation, not to scale for manufacture. Request the certified drawing (PDF / DXF / STEP) with your enquiry.

AFoot hole spacing, end190 mm
BFoot hole spacing, side140 mm
CShaft shoulder to foot hole70 mm
HShaft centre height112 mm
KFoot hole diameter12 mm
LOverall length382 mm
ACBody diameter215 mm
HDOverall height279 mm
DShaft diameter28 mm
EShaft length60 mm
MFlange B5 · pitch circle215 mm
NFlange B5 · spigot180 mm
PFlange B5 · outside diameter250 mm
SFlange B5 · hole diameter14.5 mm

Mountings B3, B5, B14, B35 and B34 on every rating. Shaft tolerance to IEC 60072. NEMA frames 56C to 256T built to MG 1 on request.

Let’s build your motor.

Send us output, speed, supply, mounting, duty and quantity. Our engineers reply with a recommendation and a quotation.