EMPD Energy Efficient Motors
Region
Get a quote
Sales & engineering

[email protected]
+91 99445 93322 · WhatsApp

North America · Europe & UK

[email protected]
+1 (215) 800-9836 · +44 7424 878268

Works

S.F. No. 450/3A, Annai Nagar, Othakalmandapam Road, Chettipalayam, Coimbatore 641 201, Tamil Nadu, India

Single-phase

EM1P-80-2-0.75

Single-phase motor · Permanent split capacitor · 0.75 kW · 2 pole · 2810 rpm

2 poleFrame 80230 V · 50 HzIP55 · IC411Duty S1SF 1.25 at 460 V 60 HzCE
Request a quote
IEC 80 · 230 V
Single-phase motor · Permanent split capacitor
Representative model from frame 80 dimensions
Tap a partDrag to rotate · scroll to zoom
0.75kWRated output · 50 Hz
2810rpmRated speed
73%Efficiency, full load
2.55NmRated torque
4.7ACurrent at 230 V
0.97Power factor
9kgWeight, B3
0.2× MNStarting torque

Performance · 50 Hz, tested values

Output0.75 kW
Poles · synchronous speed2 · 3000 rpm
Rated speed2810 rpm
Rated torque MN2.55 Nm
Current at 230 V4.7 A
DesignPermanent split capacitor
Start capacitor15 µF
Run capacitor–
Efficiency 100 / 75 / 50 %73 / 72 / 67
Power factor 100 / 75 / 50 %0.97 / 0.93 / 0.84
Efficiency classNot classified (single-phase)
Locked-rotor torque MA/MN0.2
Starting current IA/IN3.7
InsulationClass F, temperature rise class B
Enclosure · coolingIP55 · IC411 TEFC
Ambient−20 °C to +40 °C
Service factor1.0 standard · 1.15 on request

Part-load performance

5060708090100737267100 % load75 % load50 % load Efficiency %cos φ × 100

Efficiency determined to IEC 60034-2-1. Values on a 400 V winding (230 V for single-phase), subject to IEC tolerances.

60 Hz · for North America

Supply115 / 230 V · 60 Hz (wound and fitted with capacitors for 60 Hz)
Output0.75 kW · 1.01 HP
Nameplate HP1 HP
Speed3370 rpm
Torque1.57 lb-ft
FLA at 230 V / 115 V≈ 4.7 A / ≈ 9.4 A
Service factor1.0 standard · 1.15 on request

About these values

Calculated from tested 50 Hz data and confirmed by test on order. A 50 Hz motor must not be run on 60 Hz. In the US, capacitor-start motors for general-purpose use may fall under the DOE small electric motor efficiency standards.

Frames are IEC metric; NEMA frames 56C to 256T built to MG 1 on request. Please confirm certification requirements (e.g. UL / CSA) at enquiry.

Export programme

Dimensions · IM B3, frame 80

L 278CBH 80EA 125

Schematic outline for orientation, not to scale for manufacture. Request the certified drawing (PDF / DXF / STEP) with your enquiry.

AFoot hole spacing, end125 mm
BFoot hole spacing, side100 mm
CShaft shoulder to foot hole50 mm
HShaft centre height80 mm
KFoot hole diameter10 mm
LOverall length278 mm
ACBody diameter160 mm
HCOverall height208 mm
DShaft diameter19 mm
EShaft length40 mm
MFlange B5 · pitch circle165 mm
NFlange B5 · spigot130 mm
PFlange B5 · outside diameter200 mm
SFlange B5 · hole diameter12 mm

Mountings B3, B5, B14, B35 and B34 on every rating. Shaft tolerance to IEC 60072. NEMA frames 56C to 256T built to MG 1 on request.

Let’s build your motor.

Send us output, speed, supply, mounting, duty and quantity. Our engineers reply with a recommendation and a quotation.