EMPD Energy Efficient Motors
Region
Get a quote
Sales & engineering

[email protected]
+91 99445 93322 · WhatsApp

North America · Europe & UK

[email protected]
+1 (215) 800-9836 · +44 7424 878268

Works

S.F. No. 450/3A, Annai Nagar, Othakalmandapam Road, Chettipalayam, Coimbatore 641 201, Tamil Nadu, India

Single-phase

EM1P-63-2-0.18

Single-phase motor · Permanent split capacitor · 0.18 kW · 2 pole · 2870 rpm

2 poleFrame 63230 V · 50 HzIP55 · IC411Duty S1SF 1.25 at 460 V 60 HzCE
Request a quote
IEC 63 · 230 V
Single-phase motor · Permanent split capacitor
Representative model from frame 63 dimensions
Tap a partDrag to rotate · scroll to zoom
0.18kWRated output · 50 Hz
2870rpmRated speed
64%Efficiency, full load
0.57NmRated torque
1.25ACurrent at 230 V
0.98Power factor
5kgWeight, B3
0.4× MNStarting torque

Performance · 50 Hz, tested values

Output0.18 kW
Poles · synchronous speed2 · 3000 rpm
Rated speed2870 rpm
Rated torque MN0.57 Nm
Current at 230 V1.25 A
DesignPermanent split capacitor
Start capacitor15 µF
Run capacitor–
Efficiency 100 / 75 / 50 %64 / 59 / 49
Power factor 100 / 75 / 50 %0.98 / 0.97 / 0.94
Efficiency classNot classified (single-phase)
Locked-rotor torque MA/MN0.4
Starting current IA/IN3
InsulationClass F, temperature rise class B
Enclosure · coolingIP55 · IC411 TEFC
Ambient−20 °C to +40 °C
Service factor1.0 standard · 1.15 on request

Part-load performance

30405060708090100645949100 % load75 % load50 % load Efficiency %cos φ × 100

Efficiency determined to IEC 60034-2-1. Values on a 400 V winding (230 V for single-phase), subject to IEC tolerances.

60 Hz · for North America

Supply115 / 230 V · 60 Hz (wound and fitted with capacitors for 60 Hz)
Output0.18 kW · 0.24 HP
Nameplate HP1/4 HP
Speed3445 rpm
Torque0.37 lb-ft
FLA at 230 V / 115 V≈ 1.25 A / ≈ 2.5 A
Service factor1.0 standard · 1.15 on request

About these values

Calculated from tested 50 Hz data and confirmed by test on order. A 50 Hz motor must not be run on 60 Hz. In the US, capacitor-start motors for general-purpose use may fall under the DOE small electric motor efficiency standards.

Frames are IEC metric; NEMA frames 56C to 256T built to MG 1 on request. Please confirm certification requirements (e.g. UL / CSA) at enquiry.

Export programme

Dimensions · IM B3, frame 63

L 207CBH 63EA 100

Schematic outline for orientation, not to scale for manufacture. Request the certified drawing (PDF / DXF / STEP) with your enquiry.

AFoot hole spacing, end100 mm
BFoot hole spacing, side80 mm
CShaft shoulder to foot hole40 mm
HShaft centre height63 mm
KFoot hole diameter7 mm
LOverall length207 mm
ACBody diameter126 mm
HCOverall height169 mm
DShaft diameter11 mm
EShaft length23 mm
MFlange B5 · pitch circle115 mm
NFlange B5 · spigot95 mm
PFlange B5 · outside diameter140 mm
SFlange B5 · hole diameter10 mm

Mountings B3, B5, B14, B35 and B34 on every rating. Shaft tolerance to IEC 60072. NEMA frames 56C to 256T built to MG 1 on request.

Let’s build your motor.

Send us output, speed, supply, mounting, duty and quantity. Our engineers reply with a recommendation and a quotation.