EMPD Energy Efficient Motors
Region
Get a quote
Sales & engineering

[email protected]
+91 99445 93322 · WhatsApp

North America · Europe & UK

[email protected]
+1 (215) 800-9836 · +44 7424 878268

Works

S.F. No. 450/3A, Annai Nagar, Othakalmandapam Road, Chettipalayam, Coimbatore 641 201, Tamil Nadu, India

Single-phase

EM1C-90S-2-1.1

Single-phase motor · Capacitor start, induction run · 1.1 kW · 2 pole · 2875 rpm

2 poleFrame 90S230 V · 50 HzIP55 · IC411Duty S1SF 1.25 at 460 V 60 HzCE
Request a quote
IEC 90S · 230 V
Single-phase motor · Capacitor start, induction run
Representative model from frame 90S dimensions
Tap a partDrag to rotate · scroll to zoom
1.1kWRated output · 50 Hz
2875rpmRated speed
71.5%Efficiency, full load
3.65NmRated torque
8.8ACurrent at 230 V
0.76Power factor
12.5kgWeight, B3
1.5× MNStarting torque

Performance · 50 Hz, tested values

Output1.1 kW
Poles · synchronous speed2 · 3000 rpm
Rated speed2875 rpm
Rated torque MN3.65 Nm
Current at 230 V8.8 A
DesignCapacitor start, induction run
Start capacitor100 µF
Run capacitor–
Efficiency 100 / 75 / 50 %71.5 / 71 / 67
Power factor 100 / 75 / 50 %0.76 / 0.67 / 0.53
Efficiency classNot classified (single-phase)
Locked-rotor torque MA/MN1.5
Starting current IA/IN4.7
InsulationClass F, temperature rise class B
Enclosure · coolingIP55 · IC411 TEFC
Ambient−20 °C to +40 °C
Service factor1.0 standard · 1.15 on request

Part-load performance

40506070809010071.57167100 % load75 % load50 % load Efficiency %cos φ × 100

Efficiency determined to IEC 60034-2-1. Values on a 400 V winding (230 V for single-phase), subject to IEC tolerances.

60 Hz · for North America

Supply115 / 230 V · 60 Hz (wound and fitted with capacitors for 60 Hz)
Output1.1 kW · 1.48 HP
Nameplate HP1½ HP
Speed3450 rpm
Torque2.25 lb-ft
FLA at 230 V / 115 V≈ 8.8 A / ≈ 17.6 A
Service factor1.0 standard · 1.15 on request

About these values

Calculated from tested 50 Hz data and confirmed by test on order. A 50 Hz motor must not be run on 60 Hz. In the US, capacitor-start motors for general-purpose use may fall under the DOE small electric motor efficiency standards.

Frames are IEC metric; NEMA frames 56C to 256T built to MG 1 on request. Please confirm certification requirements (e.g. UL / CSA) at enquiry.

Export programme

Dimensions · IM B3, frame 90S

L 322CBH 90EA 140

Schematic outline for orientation, not to scale for manufacture. Request the certified drawing (PDF / DXF / STEP) with your enquiry.

AFoot hole spacing, end140 mm
BFoot hole spacing, side100 mm
CShaft shoulder to foot hole56 mm
HShaft centre height90 mm
KFoot hole diameter10 mm
LOverall length322 mm
ACBody diameter178 mm
HCOverall height218 mm
DShaft diameter24 mm
EShaft length50 mm
MFlange B5 · pitch circle165 mm
NFlange B5 · spigot130 mm
PFlange B5 · outside diameter200 mm
SFlange B5 · hole diameter12 mm

Mountings B3, B5, B14, B35 and B34 on every rating. Shaft tolerance to IEC 60072. NEMA frames 56C to 256T built to MG 1 on request.

Let’s build your motor.

Send us output, speed, supply, mounting, duty and quantity. Our engineers reply with a recommendation and a quotation.