EMPD Energy Efficient Motors
Region
Get a quote
Sales & engineering

[email protected]
+91 99445 93322 · WhatsApp

North America · Europe & UK

[email protected]
+1 (215) 800-9836 · +44 7424 878268

Works

S.F. No. 450/3A, Annai Nagar, Othakalmandapam Road, Chettipalayam, Coimbatore 641 201, Tamil Nadu, India

Single-phase

EM1C-71-2-0.18

Single-phase motor · Capacitor start, induction run · 0.18 kW · 2 pole · 2850 rpm

2 poleFrame 71230 V · 50 HzIP55 · IC411Duty S1SF 1.25 at 460 V 60 HzCE
Request a quote
IEC 71 · 230 V
Single-phase motor · Capacitor start, induction run
Representative model from frame 71 dimensions
Tap a partDrag to rotate · scroll to zoom
0.18kWRated output · 50 Hz
2850rpmRated speed
61%Efficiency, full load
0.6NmRated torque
1.65ACurrent at 230 V
0.77Power factor
6kgWeight, B3
2.2× MNStarting torque

Performance · 50 Hz, tested values

Output0.18 kW
Poles · synchronous speed2 · 3000 rpm
Rated speed2850 rpm
Rated torque MN0.6 Nm
Current at 230 V1.65 A
DesignCapacitor start, induction run
Start capacitor55 µF
Run capacitor–
Efficiency 100 / 75 / 50 %61 / 60 / 52
Power factor 100 / 75 / 50 %0.77 / 0.67 / 0.56
Efficiency classNot classified (single-phase)
Locked-rotor torque MA/MN2.2
Starting current IA/IN5.3
InsulationClass F, temperature rise class B
Enclosure · coolingIP55 · IC411 TEFC
Ambient−20 °C to +40 °C
Service factor1.0 standard · 1.15 on request

Part-load performance

405060708090100616052100 % load75 % load50 % load Efficiency %cos φ × 100

Efficiency determined to IEC 60034-2-1. Values on a 400 V winding (230 V for single-phase), subject to IEC tolerances.

60 Hz · for North America

Supply115 / 230 V · 60 Hz (wound and fitted with capacitors for 60 Hz)
Output0.18 kW · 0.24 HP
Nameplate HP1/4 HP
Speed3420 rpm
Torque0.37 lb-ft
FLA at 230 V / 115 V≈ 1.65 A / ≈ 3.3 A
Service factor1.0 standard · 1.15 on request

About these values

Calculated from tested 50 Hz data and confirmed by test on order. A 50 Hz motor must not be run on 60 Hz. In the US, capacitor-start motors for general-purpose use may fall under the DOE small electric motor efficiency standards.

Frames are IEC metric; NEMA frames 56C to 256T built to MG 1 on request. Please confirm certification requirements (e.g. UL / CSA) at enquiry.

Export programme

Dimensions · IM B3, frame 71

L 238CBH 71EA 112

Schematic outline for orientation, not to scale for manufacture. Request the certified drawing (PDF / DXF / STEP) with your enquiry.

AFoot hole spacing, end112 mm
BFoot hole spacing, side90 mm
CShaft shoulder to foot hole45 mm
HShaft centre height71 mm
KFoot hole diameter7 mm
LOverall length238 mm
ACBody diameter140 mm
HCOverall height197 mm
DShaft diameter14 mm
EShaft length30 mm
MFlange B5 · pitch circle130 mm
NFlange B5 · spigot110 mm
PFlange B5 · outside diameter160 mm
SFlange B5 · hole diameter10 mm

Mountings B3, B5, B14, B35 and B34 on every rating. Shaft tolerance to IEC 60072. NEMA frames 56C to 256T built to MG 1 on request.

Let’s build your motor.

Send us output, speed, supply, mounting, duty and quantity. Our engineers reply with a recommendation and a quotation.