EMPD Energy Efficient Motors
Region
Get a quote
Sales & engineering

[email protected]
+91 99445 93322 · WhatsApp

North America · Europe & UK

[email protected]
+1 (215) 800-9836 · +44 7424 878268

Works

S.F. No. 450/3A, Annai Nagar, Othakalmandapam Road, Chettipalayam, Coimbatore 641 201, Tamil Nadu, India

Home/Motor finder/Brake motor/EBM-A160M-6-7.5
Brake motor · AC brake

EBM-A160M-6-7.5

Brake motor · AC brake · 7.5 kW · 6 pole · 975 rpm

IE26 poleFrame 160M400/690 V · 50 HzIP55 · IC411Duty S4CE
Request a quote
IEC 160M · 400/690 V
Brake motor · AC brake
Representative model from frame 160M dimensions
Tap a partDrag to rotate · scroll to zoom
7.5kWRated output · 50 Hz
975rpmRated speed
87.2%Efficiency, full load
73.5NmRated torque
16.6ACurrent at 400 V
0.75Power factor
84kgWeight, B3
1.8× MNStarting torque

Performance · 50 Hz, tested values

Output7.5 kW
Poles · synchronous speed6 · 1000 rpm
Rated speed975 rpm
Rated torque MN73.5 Nm
Current at 230 V–
Current at 400 V16.6 A
Current at 690 V–
Efficiency 100 / 75 / 50 %87.2 / 88.1 / 86.2
Power factor 100 / 75 / 50 %0.75 / 0.67 / 0.56
Efficiency classIE2 (IEC 60034-30-1)
Locked-rotor torque MA/MN1.8
Starting current IA/IN6.5
Breakdown torque MK/MN2.8
Rotor inertia J0.1 kgm²
Sound pressure LPA at 1 m59 dB(A)
InsulationClass F, temperature rise class B
Enclosure · coolingIP55 · IC411 TEFC
Ambient−20 °C to +40 °C
Service factorNot applicable to S4 hoist duty; S1 versions SF 1.15 at 50 Hz

Torque–speed curve indicative

1×2×3×4× MAMKMN02505007501000speed · rpmtorque ÷ MN

Drawn through the catalogue points MA, MS, MK and MN. Request the tested curve for your application.

Part-load performance

40506070809010087.288.186.2100 % load75 % load50 % load Efficiency %cos φ × 100

Efficiency determined to IEC 60034-2-1. Values on a 400 V winding (230 V for single-phase), subject to IEC tolerances.

60 Hz · for North America

Supply460 V · 60 Hz
Output (calculated)8.62 kW · 11.57 HP
Nameplate HP10 HP
Speed1170 rpm
Torque51.92 lb-ft · 70.39 Nm
Full-load amps at nameplate HP≈ 15.38 A
Service factorNot applicable to S4 hoist duty

About these values

Calculated from EMPD tested 50 Hz / 400 V data (output × 1.15, speed × 1.2) and confirmed by test on order with a 60 Hz test certificate. Continuous-duty (S1) motors sold in the US must meet NEMA Premium efficiency and be DOE-certified. Please contact EMPD to discuss.

Frames are IEC metric; NEMA frames 56C to 256T built to MG 1 on request. Please confirm certification requirements (e.g. UL / CSA) at enquiry.

Export programme

Brake selection · AC brake

100 % of motor torqueEBA-16 · 75 Nm
150 % of motor torqueNot offered
200 % of motor torque · hoistNot offered
250 % of motor torqueNot offered

Selecting the brake

Spring-applied, fail-safe AC brake. Choose 150 % for general machinery and 200 % for hoists. A red percentage shows the maximum brake torque available for this frame where it is below the column value. Brake coils for 230 V, 400 V or 460 / 575 V AC; manual release, micro switch and force-voltage rectifier options.

Brake sizing tool

Dimensions · IM B3, frame 160M

L 737CBH 160EA 254

Schematic outline for orientation, not to scale for manufacture. Request the certified drawing (PDF / DXF / STEP) with your enquiry.

AFoot hole spacing, end254 mm
BFoot hole spacing, side210 mm
CShaft shoulder to foot hole108 mm
HShaft centre height160 mm
KFoot hole diameter15 mm
LOverall length incl. brake737 mm
ADCentre to terminal box top266 mm
DShaft diameter42 mm
EShaft length110 mm
MFlange B5 · pitch circle300 mm
NFlange B5 · spigot250 mm
PFlange B5 · outside diameter350 mm
SFlange B5 · hole diameter18.5 mm

Mountings B3, B5, B14, B35 and B34 on every rating. Shaft tolerance to IEC 60072. NEMA frames 56C to 256T built to MG 1 on request.

Let’s build your motor.