Elevators & lifts. Smooth from floor to floor.
Low-inertia motors that accelerate and stop quickly and smoothly.
Background: representative footage
The duty
Fast acceleration, gentle stops.
Elevator motors are designed for rapid acceleration and retardation, so the inertia of their moving parts is kept as low as possible.
EMPD supplies complete motor solutions for elevators and lifts to each OEM's specification.
Applications
What the duty demands
- Low rotor inertia for smooth stops
- Dual speed or VVVF drive
- Quiet running
Specifications
The range, at a glance.
Typical range for elevators & lifts. Every motor is built to your specification; tell us the duty and we confirm the design.
3~ · IEC 60034
| OUTPUT | UP TO 15 kW |
| SPEEDS | SINGLE SPEED OR DUAL SPEED |
| MOUNTING | B3, B5, B14 AND COMBINATIONS, OR SPECIAL MOUNTING |
| SUPPLY | 415 V ±10 %, 50 Hz ±5 %, OR AS REQUIRED |
| CONSTRUCTION | FULL CAST IRON |
Recommended products
Motors for elevators & lifts.
Dual speedPole-changing motors for a fast and a creep speed from one frame.
63–160L · 0.18–15 kW→
Brake motorsSpring-applied DC or AC brakes from 0.8 to 160 Nm, sized at 100–250 % of motor torque.
EBM-D132S-4-5.5 · 5.5 kW→Example ratings
| Model | kW | Poles | rpm | Efficiency | Brake |
|---|---|---|---|---|---|
| EBM-D132S-4-5.5 | 5.5 | 4 | 1455 | 87.7 % | DC |
| EBM-D112M-4-4 | 4 | 4 | 1440 | 86.6 % | DC |
Proof
Evidence, not adjectives.
Built to your specification
Tell us the duty
Send the duty, supply and mounting. Our engineers reply with a recommendation and a quotation.
Application study
Running a brake motor on an inverter
Read the worked example →
Test reports
Every motor routine tested
See real routine and type test reports from our lab →
FAQ
Questions, answered.
What motors does EMPD make for elevators & lifts?
The typical range is output up to 15 kW; single speed or dual speed. Construction: full cast iron. EMPD builds each motor to the OEM's specification for the duty, supply and mounting.
Where are EMPD motors used in elevators & lifts?
Passenger and goods lifts and escalators.
What does a motor for elevators & lifts need?
Low rotor inertia for smooth stops. Dual speed or VVVF drive. Quiet running. EMPD designs, builds and routine tests every motor in its own plant in Coimbatore, India.
Can EMPD supply motors for 60 Hz markets and with CE marking?
Yes. Every catalogue rating has 460 V 60 Hz data in the online motor finder, and three-phase IE2 / IE3 motors for 60 Hz carry a service factor of 1.25. NEMA frames 56C to 256T are built to MG 1 on request. For Europe and the UK, EMPD holds a CE attestation of conformity from DEKRA covering single-phase motors from 0.18 to 3.7 kW, three-phase motors from 0.18 to 15 kW, and BLDC and PMSM motors.
How do I get a quote?
Send the output, speed, supply, mounting, duty and quantity through the quote form on empdrives.com, by email to [email protected], or on WhatsApp. EMPD's engineers reply with a recommendation and a quotation.










